50Hz Performance
- Single stage blower performance Max. air flow to 1134 m3/H and Max. air pressure to 450 mbar (Model SS-9220).
- Two stage blower (high pressure design) Max. air flow to 575 m3/H and Max. air pressure to 580 mbar (Model TS-83190).
- Two stage blower (large air flow design) Max. air flow to 850 m3/H and Max. air pressure to 270 mbar (Model TS-84130).
60Hz Performance
- Single stage blower performance with Max. air flow to 1344 m3/H and Max. air pressure to 430 mbar (Model SS-9220).
- Two stage blower (high pressure design) Max. air flow to 645 m3/H and Max. air pressure to 780 mbar (Model TS-83190).
- Two stage blower (large air flow design) Max. air flow to 990 m3/H and Max. air pressure to 270 mbar (Model TS-84130).
Notes
- Side Channel Blower performance is valid with atmosphere 1 bar (abs.) ,inlet air temperature 20°C and air density 1.2kg/m3, allowable tolerance as ±10%.
- Installation altitude – Max. above sea level 1000M [ 3280ft ]
- Do not touch the blower surface, blower surface temperature during operation may up to 160°C (320°F)
- Do not dispose of acid, alkali or flammable gas, otherwise explosion and damage may occur.
Storage conditions
- Dry
- Dust-free
- Low vibration (< 2.8mm/s)
- Ambient temperature < 40°C (104°F)